-40%
0.1-60MHz 20MHz~2.4GHz RF Signal Frequency Counter Cymometer Tester LED Display
$ 6.56
- Description
- Size Guide
Description
0.1-60MHz 20MHz~2.4GHz RF Signal Frequency Counter Cymometer Tester LED DisplayDescription
:
With Microchip's PIC16F648A, 2.4 GHz frequency meter.
Using temperature-compensated voltage controlled crystal oscillator (2.5 ppm VC-TCXO).
Unique gate control and precise time algorithm (non-timed interrupt).
Gate (display refresh) time 0.01 seconds / 0.1 seconds / 1.0 seconds, real-time display frequency value.
Single-ended input design, three-channel frequency measurement (low channel / high channel / Auto Channel).
Dual frequency design, value and IF / down mode can be preset separately.
Using eight 0.56 inches high brightness digital display, eight adjustable brightness.
Circuit is simple and reasonable structure, two-button control, simple operation.
The settings are automatically saved, boot directly call.
Descriptions:
1 Gate time
0.01 秒
0.10 秒
1.0 秒
2 Measurement channels (channels are low impedance)
low channel
Measuring range: 0.1 MHz ~ 60 MHz
Accuracy: ± 100Hz (0.01 1s gate time)
± 10Hz (0.1 seconds gate)
± 1Hz (1.0 seconds when the gate)
Low channel sensitivity:
0.1 MHz ~ 10 MHz: better than 60mVPP
10 MHz ~ 60 MHz: better than 60mVPP
60 MHz ~ 75 MHz: Not tested
high channel (divided by 64)
Measuring range: 20 MHz ~ 2.4 GHz
Accuracy: ± 6400Hz (0.01 seconds gate)
± 640Hz (0.1 1s gate time)
± 64Hz (1.0 1s gate time)
High channel sensitivity:
20 MHz ~ 30 MHz: better than 100mVPP
30 MHz ~ 60 MHz: better than 50mVPP
60 MHz ~ 2.4GHz: not tested
Auto Channel
Automatically selected according to the input signal frequency high or low channel channel, identifying the frequency of 60 MHz. Such as when the input signal amplitude is greater than 60 MHz shortage can not automatically select high channel, the channel should manually select high frequency measurement.
3,IF settings
Independent double-IF design, adjust the minimum frequency step of 100 Hz,frequency range 0 ~ 99.9999 MHz, can be set to increase or decrease the IF frequency mode.
4. Frequency reference
Using 5032 package 13.000MHz Warming voltage controlled crystal oscillator (VC-TCXO), frequency stability of ± 2.5 ppm.
5. Operating voltage
DC Input: DC 9V ~ 15V (with reverse polarity protection)
6 Current
Maximum 160 mA (test conditions: ① DC12V power supply; ② red LED; ③ eight brightness)
7 Eight LED display, the highest display eight digits.
8 Eight LED brightness is adjustable, factory set to maximum brightness.
9 Physical Dimensions,Length × width × height: 125.5 mm × 25.5 mm × 21.5 mm
10. Component quality 46 g (NW)
11. Onboard Interface
DC IN (Power Interface): HX2.54-2P socket
RF IN (signal input): HX2.54-2P socket
ICSP (programming interface): 2.54-6P Pin
Color: Red,Blue and Green
Package included :
1 x 0.1-60MHz 20MHz ~ 2.4GHz RF Singal Frequency Counter Cymometer Tester Meter
Why buy from us
Payment
Shipping
Refund
Why buy from us
We offer quality products at a reasonable price.
We provide Fast and Free Shipping for our products.
Our customer service is available to you before, during and after the sale.
Payment
We only accept payment through Paypal.
Items will go to post within 1-2 business days after payment confirmed.
Shipping
1. We ship to Worldwide.
2. We only ship to confirmed PAYPAL address; your PAYPAL address must match your Shipping address.
3. Any non-received items caused by invalid address registered on PayPal are not in our full refund or replacement policy. Shipping fee has including the local handing and packaging fee.
4. All the items will be shipping within 1-2 working days after receiving the payment, except some holidays.
5. We will not be responsible for any custom delay or tax, because transit time is highly depended and provided by postal Service.
6. If you have any problem, please contact us via message, we will reply message within 1-2 working days, please wait for patient.
Refund
If you can't receive the product within 2 months (60 days), please contact with us,we promise to payback 100% of your money.
We ensure our products work normally before post.If the products is broken before arrival to you,all you should do is taking a photo to show us our broken product.We promise to payback 100% of your money.
If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.